2" Vertical Boiler Custom Engine Steam Plant
Steam Plant comes with:
Exhaust oil trap P/N 4062
2" Copper High Performance Boiler P/N 4057
Refillable gas tank with pressure test certificate. P/N 4271
Gas filler adapter P/N 4358
Brass mounting tray P/N 2737
Gas & steam pipe work
Probably special steam connectors to custom engine if discussed at time of ordering
Syringe for emptying oil trap
Not Supplied:
Engine.
Steam Plant Specifications:
Weight dry 1.26 kg
Tray Size 85 x 180 mm with engine space 85 x 75 mm to 100 mm
Height to top of boiler cone 140 mm
Height to top of flue 200 mm
Boiler specifications:
Diameter 2” 50.8 mm
Boiler water capacity 75 ml
Working pressure 25 psi 2.07 bar
Test pressure 80 psi 5.32 bar
Running time Approx. 15 min at 20 psi
Complies with the following design, construction and testing requirements of:
- Australian Standard AS 4343 Level E
- Australian Miniature Boiler Safety Committee, (AMBSC) code part 3 Issue 1.0 - 2006 Sub-Miniature Boilers and AMBSC code part I . Issue 7 - 2001 - UK Boiler Test Code 2018 – Volume 2
Copper Boiler includes:
Pressure gauge
Safety valve
Water sight glass
Gas fired cast ceramic burner
Pressure test certificate